Model Number: MA5800-X17
Huawei MA5800-X17 GEPON OLT
the next-generation OLT for NG-PON
Ultra-Bandwidths Smart Capabilities Fixed Mobile Convergence(FMC)
Switching Capacity of the system |
7 Tbit/s |
Each service slot |
switching capability: 200 Gbit/s. Available MAC address: 256K |
Benefits: non-blocking access for high-density XG-PON and 40G-PON | |
Each sub-rack | supports up to 32K users with 100 Mbit/s of non-blocking bandwidth |
Benefits: seamless 4K video viewing | |
PON/P2P | Full-service PON/P2P access for home, enterprise, and mobile backhaul |
creates a single optical network with FMC services |
Maximum Number of Ports in a Subrack | GPON/EPON | 272 |
GE/FE | 816 | |
XG-PON: 10G GPON /10G EPON / 10G GE | 136 | |
E1 | 544 |
GPON Board | 16 ports with Class B+/C+ SFP optical modules; eOTDR; 40 km differential reach; 4-level HQoS; 1588v2 |
XG-PON Board | 8 ports with SFP+ optical modules; 40 km differential reach; 4-level HQoS; 1588V2 |
Ethernet 10 GE Board | 8 x 10 GE SFP+ interface or 8 x GE SFP/eSFP interface; SyncE and 1588v2 |
Layer 2 Features | VLAN + MAC forwarding, SVLAN + CVLAN forwarding, PPPoE+, and DHCP option82 |
Layer 3 Features | Static route, RIP/RIPng, OSPF/OSPFv3, IS-IS, BGP/BGP4+, ARP, DHCP relay, and VRF |
MPLS & PWE3 | MPLS LDP, MPLS RSVP-TE, MPLS OAM, MPLS BGP IP VPN, tunnel protection switching, TDM/ETH PWE3, and PW protection switching |
IPv6 | IPv4 / IPv6 dual stack, IPv6 L2 and L3 forwarding, and DHCPv6 relay |
Multicast | IGMP v2/v3, IGMP & MLD proxy/snooping, MLD v1/v2, and VLAN-based IPTV multicast |
QoS | Traffic classification, priority processing, trTCM-based traffic policing, WRED, traffic shaping, HqoS, PQ/WRR/PQ + WRR, and ACL |
System Reliability | GPON type B/type C protection, 10G GPON type B protection, BFD, ERPS (G.8032), MSTP, intra-board and inter-board LAG, In-Service Software Upgrade (ISSU) of the control board, 2 control boards and 2 power boards for redundancy protection, in-service board fault detection and rectification, and service overload control |
Ambient Temperature |
-40°C to 65°C start up: -25°C and run: -40°C. 65°C is the highest temperature measured at the air intake vent |
Working Voltage | -38.4V DC to -72V DC |
Intelligent
LPU programmable NP architecture that supports SDN based intelligent services to support the rapid deployment of new services;
It supports virtual access network functions, to achieve multi-service network intelligence operations or conduct wholesale business, providing a better service experience.